In addition to strict and reasonable coating design, the quality of each link must be ensured in the construction of the entire anticorrosive floor paint paint. The negligence of any link may have a serious impact on the overall quality of floor paint projects. Therefore, all personnel involved in construction must strictly implement the floor paint paint craft documents.


(1) Before coating construction, the floor paint construction personnel should carefully read the coating process file of the paint paint system of the floor paint project. Understand, master the coating support, read the ping paint product instructions and its construction guidance of the floor paint company.


(2) The floor paint coating for floor paint paint must be checked. It is forbidden to mix different varieties, different brands and floor paint of different manufacturers.


(3) The sprayed ground level surface must be reported and confirmed that the technical indicators such as the surface treatment level, surface cleanliness, roughness and other technical indicators must be reported.


(4) Confirm the environmental conditions such as temperature, relative humidity such as temperature, relative humidity, etc.


(5) Check the models, batch numbers, color numbers, quantity, etc. of the paint paint coatings used in the inspection; pay special attention to the construction of dual -component flooring paint paint, including the mixed ratio of curing agent and base material, mixed use time and curing agent Type, correctly use the diluent, pay attention to adjust the construction viscosity of the paint paint coatings at any time as the construction environment temperature and humidity changes to prevent dry spraying and flowing.


(6) The time interval of the lacquer paint processing process strictly abides by the re -coating time interval specified in the instructions of the floor paint paint product.


(7) The number of dual -component flooring paint coatings must be compatible with the workload, the mixed use time of floor paint coatings, the construction manpower, and the operation class. The mixing ratio should be accurate, and add the volume ratio.